Verona WALL HUNG GAS BOILER Gas Heater User Manual


 
5. Electric Diagrams
ye bk whgy bu rd
bk
gy
gy
gy
M
~
t
probe NTC
C.h. temperature
COM
NO
M
~
COM
NO
NC
123
bk
bubn
rd
rd
gnyegywh
bu
rd
bk
bu
wh
gybugnye
bk bk
gygnye bu
bk
bk
bubu
bu
bu
rdbk
gygy
L N
rd bu bn gnye gnye
gnye bubn
burd
gnye
Flow Switch
Primary Circuit Pump
Valve
Gas
External controls
terminal
block
Electric supply
terminal
block
Fan Safety
Thermostat
Air Pressure
Switch
Ignition
Electrodes
Flame Detection
Electrode
bn - brown
bu - blue
bk - black
wh - white
rd - red
gy - grey
ye - yellow
gnye - green/yellow
wh
gy
rd
rd
bk
bu
bn
gy
ye wh bu
rd
1
bk
rd
*
* ---> directly connected to the electronic ignition board
Caution: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing
RIVA HEAT ONLY MANUAL - REV A
13