23
Performance
Data
SSP-PRC002-EN
(System)
Table PD-12 — Gross Heating Capacities (MBh)
TWA200B Heat Pump with TWE200B Air Handler At 6675 CFM (I-P)
Outdoor Heating Capacity (BTUH/1000) At Total Power in Kilowatts At
Temperature Indicated Indoor Dry Bulb Temperature Indicated Indoor Dry Bulb Temperature
(°F) 60 70 75 80 60 70 75 80
-18 43.5 80.3 85.7 88.4 10.8 14.5 15.6 16.5
-13 68.9 87.1 91.0 93.0 12.3 14.8 15.8 16.7
-8 82.3 94.2 97.0 98.4 13.0 15.1 16.0 16.8
-3 93.2 101.6 103.6 104.5 13.4 15.3 16.2 17.1
2 103.5 109.4 110.8 111.3 13.8 15.6 16.4 17.3
7 113.7 117.8 118.6 118.8 14.1 15.8 16.7 17.6
12 124.2 126.8 127.2 127.1 14.5 16.1 17.0 17.9
17 135.0 136.4 136.5 136.1 14.8 16.4 17.3 18.2
22 146.2 146.7 146.5 146.0 15.1 16.7 17.6 18.5
27 157.9 157.6 157.2 156.6 15.4 17.1 18.0 18.9
32 170.2 169.3 168.8 168.1 15.7 17.4 18.4 19.4
37 182.4 181.2 180.5 179.8 16.0 17.8 18.8 19.8
42 195.1 193.5 192.7 192.0 16.4 18.2 19.2 20.3
47 208.4 206.5 205.7 205.0 16.7 18.6 19.7 20.8
52 222.4 220.3 219.4 218.7 17.2 19.1 20.2 21.3
57 236.9 234.6 233.6 232.9 17.6 19.6 20.7 21.9
62 251.7 249.2 248.2 247.4 18.1 20.1 21.2 22.4
67 266.7 264.0 262.9 262.1 18.5 20.6 21.8 23.0
72 282.3 279.4 278.2 277.2 19.1 21.2 22.4 23.7
Table PD-12 — Gross Heating Capacities (kW)
TWA200B Heat Pump with TWE200B Air Handler At 11340 m
3
/h (SI)
Outdoor Heating Capacity (kW) At Total Power in Kilowatts At
Temperature Indicated Indoor Dry Bulb Temperature Indicated Indoor Dry Bulb Temperature
(°C) 15.6 21.1 23.9 26.7 15.6 21.1 23.9 26.7
27.8 12.7 23.5 25.1 25.9 5.5 6.0 6.2 6.5
-25.0 20.2 25.5 26.6 27.2 5.6 6.1 6.3 6.6
-22.2 24.1 27.6 28.4 28.8 5.7 6.2 6.5 6.7
-19.4 27.3 29.7 30.3 30.6 5.8 6.3 6.6 6.9
-16.7 30.3 32.0 32.4 32.6 5.9 6.5 6.7 7.0
-13.9 33.3 34.5 34.7 34.8 6.0 6.6 6.9 7.2
-11.1 36.4 37.1 37.2 37.2 6.2 6.7 7.0 7.4
-8.3 39.5 39.9 40.0 39.9 6.3 6.9 7.2 7.5
-5.6 42.8 42.9 42.9 42.7 6.5 7.0 7.4 7.7
-2.8 46.2 46.2 46.0 45.9 6.6 7.2 7.5 7.9
0.0 49.8 49.6 49.4 49.2 6.8 7.4 7.7 8.1
2.8 53.4 53.0 52.8 52.6 6.9 7.6 7.9 8.3
5.6 57.1 56.7 56.4 56.2 7.1 7.8 8.1 8.5
8.3 61.0 60.5 60.2 60.0 7.3 8.0 8.4 8.8
11.1 65.1 64.5 64.3 64.0 7.5 8.2 8.6 9.0
13.9 69.4 68.7 68.4 68.2 7.7 8.4 8.8 9.2
16.7 73.7 73.0 72.7 72.4 7.9 8.7 9.1 9.5
19.4 78.1 77.3 77.0 76.7 8.1 8.9 9.3 9.8
22.2 82.7 81.8 81.5 81.2 8.4 9.2 9.6 10.0
Correction Factors - Other Airflows
(Table Value x Correction Factor = Value at new airflow)
Airflow 6000 cfm 7325 cfm
10193 m
3
/h 12444 m
3
/h
Heating Capacity x 0.99 x 1.01
Compressor kW x 1.02 x 0.98
Values at ARI Rating Conditions of:
70F (21.1C) and 47/43F (8.3/6.1C)(High Temp.Cond.)
70F (21.1C) and 17/15F (-8.3/-9.4C)(Low Temp. Cond)
Airflow = 6675 cfm (11340 m
3
/h)
Heating Capacity (High Temp.) = 206,000 (60.26)
Heating Capacity (Low Temp.) = 135,000 (39.66)
Compressor Power (High Temp) = 14.92 kW
Compressor Power (Low Temp) = 12.62 kW
Coeff. Of Perf. (High Temp) = 3.2
Coeff. Of Perf. (Low Temp) = 2.4
Outdoor Fan Power = 1,100 watts
Indoor Fan Power = 2,290 watts
Note:
1. Rated with 25 feet of 1-3/8” suction and 1/2" liquid line."