– 32 –
TEMPORARY
TEMPORARY
button
TEMPORARY button Control
OFF → ON Temporary Auto operation start
After pushing button
Auto Restart control select
for 3 seconds
After pushing button Temporary Cooling
for 10 seconds operation start
Table 8-3-1
8-3-1. Temporary Auto Operation
• When the TEMPORARY button is pushed, the
Auto operation with set temperature fixed at 25°C
starts. Controlling is same as that of Auto opera-
tion by the remote controller.
• When the TEMPORARY button is pushed again,
the operation stops.
• During Temporary Auto operation, operation by
the remote controller is accepted.
• Using the Auto Restart function, the Temporary
Auto operation starts when power failure is reset.
8-3-2. Temporary Cooling Operation
• When the TEMPORARY operation button keeps
pushed for 10 seconds, Cooling operation of
which compressor motor speed and the indoor
fan speed are fixed starts.
Compressor motor speed :
10 : 30 rps
13 : 30 rps
Indoor fan speed : Low
• When the TEMPORARY operation button is
pushed again, the operation stops.
• Auto Restart function is unavailable.
8-2-4. Automatic Operation
(1) As shown in Fig. 8-2-9, the operation mode
(COOL, DRY, HEAT) is selected according to the
outside temperature and room temperature
when the operation has started.
The operation in Fan mode continues until an
operation mode is selected.
If the room temperature is 20°C or higher when
“AUTO” operation started within 2 hours after
“HEAT” operation had stopped, select an opera-
tion mode after Fan operation of ultra low fan.
In AUTO operation, the set temperature of each
operation can be corrected by the remote
controller in the range of 17 to 30°C.
Fig. 8-2-9
8-3. Temporary Operation
• Temporary Auto operation, existence of Auto
Restart, and Temporary Cooling operation can be
set by the TEMPORARY button of the indoor
controller.
(2) After selecting the operation mode (COOL, DRY,
HEAT), select an operation mode again when a
status that the compressor was turned off by the
room temperature or outside air temperature
continues for 15 minutes.
(3) Powerful Cool mode control
When the outside temperature is above 32°C
and indoor temperature is above 28°C, select
Cool mode control. In Cool mode, the air flow
louver directs downward. When the room tem-
perature gains access to the set temperature, it
becomes cool memory position.
TA
28
26
24
23
20
5
–2 –10+1
15 18 24 32 To
Ts correction by outside
temperature ( To)
Heating with setting
on remote controller
Ts = 25˚C
Powerful Cooling/Drying with
setting on remote controller
Ts = 25˚C
Cooling/Drying with setting on remote controller
Ts = 25˚C
Monitoring
(Follow to the Fan control in previous
mode when being selected again.)