Toshiba RAS-13UAV-E2 Air Conditioner User Manual


 
– 4 –
FILE NO. SVM-03008
1-2. Operation Characteristic Curve
<Cooling> <Heating>
7
6
5
4
3
2
1
0
Current (A)
Compressor speed (rps)
0 20 40 60 80 100
Conditions
Indoor : DB 27°C/WB 19°C
Outdoor : DB 35°C
Air flow : High
Pipe length : 5m
230V
7
6
5
4
3
2
1
0
Current (A)
Compressor speed (rps)
0 20 40 60 80 100
Conditions
Indoor : DB 20°C
Outdoor : DB 7°C/WB 6°C
Air flow : High
Pipe length : 5m
230V
1-3. Capacity Variation Ratio According to Temperature
<Cooling> <Heating>
120
110
100
90
80
70
60
50
40
30
20
10
0
10
9
8
7
6
5
4
3
2
1
012345678910
Capacity ratio (%)
Outdoor temp. (°C)
Conditions
Indoor : DB 20°C
Indoor air flow : High
Pipe length : 5m
*
Capacity ratio : 100% = 3.5 kW
105
100
95
90
85
80
75
70
65
60
55
50
32 34
36 38 40 4233 35 37 39 41 43
Outdoor temp. (°C)
Capacity ratio (%)
Conditions
Indoor : DB27°C/WB19°C
Indoor air flow : High
Pipe length 5m
Current Limited Start