1. SPECIFICATIONS
1-1. Specifications
Unit model Indoor RAS-13UKV-E2
Outdoor RAS-13UAV-E2
Current limited —
Cooling capacity (kW) 3.5
Cooling capacity range (kW) 0.9 – 4.0
Heating capacity (kW) 4.2
Heating capacity range (kW) 0.9 – 6.0
Power supply 220 – 240V –1Ph –50/60Hz
Electric Indoor Operation mode Cooling Heating
characteristics Running current (A) 0.15 0.15
Power consumption (W) 30 30
Power factor (%) 87 87
Outdoor Operation mode Cooling Heating
Running current (A) 4.65 5.01
Power consumption (W) 1020 1100
Power factor (%) 95 95
Starting current (A) 5.31
COP (Cooling / Heating) 3.33/3.72
Operation noise Indoor High (Cooling / Heating) (dB•A) 39/39
Medium (Cooling / Heating) (dB•A) 33/34
Low (Cooling / Heating) (dB•A) 26/28
Outdoor (Cooling / Heating) (dB•A) 48/50
Indoor unit Unit model RAS-13UKV-E2
Dimension Height (mm) 275
Width (mm) 790
Depth (mm) 208
Net weight (kg) 10
Fan motor output (W) 30
Air flow rate (Cooling / Heating) (m
3
/h) 530/620
Outdoor unit Unit model RAS-13UAV-E2
Dimension Height (mm) 550
Width (mm) 780
Depth (mm) 720
Net weight (kg) 40
Compressor Motor output (W) 750
Type Twin rotary type with DC-inverter variable speed control
Model DA91A1F-45F
Fan motor output (W) 43
Air flow rate (Cooling / Heating) (m
3
/h) 2410/2410
Piping connection Type Flare connection
Indoor unit Liquid side ∅6.35
Gas side ∅9.52
Outdoor unit Liquid side ∅6.35
Gas side ∅9.52
Maximum length (Per unit) (m) 15
Maximum chargeless length (m) 15
Maximum height difference (m) 10
Refrigerant Name of refrigerant R410A
Weight (kg) 0.9
Wiring connection Power supply 3 Wires: includes earth (Outdoor)
Interconnection 4 Wires: includes earth
Usable temperature range Indoor (Cooling / Heating) (°C) 21 – 32 / 0 – 28
Outdoor (Cooling / Heating) (°C) 10 – 43 / –10 – 24
Accessory Indoor unit Installation plate 1
Wireless remote control 1
Remote controller holder 1
Flat head wood screw 2 (∅3.1 x 16L)
Purifying filter 1
Zeolite filter 1
Batteries 2
Mounting screw 6 (∅4 x 25L)
Installation manual 1
Owner’s manual 1
Outdoor unit Drain nipple 1
• The specification may be subject to change without nitice for purpose of improvement.