Toshiba RAS-09LAV-UL Air Conditioner User Manual


 
91
11-8-5. Checking Method for Each Part
No.
1
Part name
Electrolytic capacitor
(For boost, smoothing)
Checking procedure
1. Turn OFF the power supply breaker.
2. Discharge all three capacitors completely.
3. Check that safety valve at the bottom of capacitor is not broken.
4. Check that vessel is not swollen or exploded.
5. Check that electrolytic liquid does not blow off.
6. Check that the normal charging characteristics are shown in continuity test by
the tester.
MCC-5009
Soldered
surface
Heat sink IGBT side
C12 C13 C14
Case that product is good
Pointer swings once, and returns
slowly. When performing test
once again under another
polarity, the pointer should return.
C12, C13, C14 500µF
Resistance value
in good product
Tester rod
+
~
2
~
3
~
2
~
3
4
~~
~
+ ~
1
123
(DB
01)
4
4
23
+
1
+
10 to 20 when the multimeter probe
is reversed
2 Diode block 1. Turn OFF the power supply breaker.
2. Completely discharge the four electrolytic capacitors.
3. Remove the diode block from the PCB (which is soldered in place).
4. Use a multimeter with a pointer to test the continuity, and check that the
diode block has the proper rectification characteristics.
FILE NO. SVM-10019