Toshiba RAS-09LAV-UL Air Conditioner User Manual


 
Remote controller A- B selection
To separate using of remote controller for each indoor
unit in case of 2 air conditioner are installed nearly.
Remote controller B Setup.
1. Push RESET button on the indoor unit to turn the
air conditioner ON.
2. Point the remote controller at the indoor unit.
3. Push and hold CHK button on the remote controller
by the tip of the pencil.
“00” will be shown on the display.
4. Push MODE during pushing CHK, “B” will show on
the display and “00” will disappear and the air
conditioner will turn OFF.
The remote controller B is memorized.
Note :
1. Repeat above step to reset Remote Controller to
be A.
2. Remote controller A have not “A” display.
3. Detault setting of remote controller from factory is A.
10-7-5. Remote Controller A or B Selection
Setting
When two indoor units are installed in the
separated rooms, it is not necessary to change
the selector switches.
Remote controller A or B selection
When two indoor units are installed in the same
room or adjacent two rooms, if operating a unit,
2 units may receive the remote controller signal
simultaneously and operate. In this case, the
operation can be preserved by setting either one
indoor unit or remote controller to B setting.
(Both are set to A setting in factory shipment.)
The remote controller signal is not received when
the settings of indoor unit and remote controller are
different.
There is no relation between A setting/B setting and A
room/B room when connecting the piping and cables.
Fig. 10-5-1
1. Push and hold CHK button on the Remote
Control by the tip of the pencil, "00" will be
shown on the display.
2. Press SLEEP during pushing CHK
Temperature unit °F - °C selection
Note :
1. Repeat above step to reset Remote Controller to
be °F.
2. Operation mode and temperature set will reset to
initial setting after change the temperature unit.
3. Default setting of Remote Control from factory
is °F.
PRESET FAN
“B” Display
“00” Display
FILE NO. SVM-10019
– 65 –