12
EN
This function is usable for prevention of freeze of an uninhabited room.
Press this button to start the 8°C set temperature heating operation.
The air conditioner controls the room temperature to about 8°C.
The room temperature may deviate slightly from 8°C depending on the size of the room
and the installation condition of the unit.
Starting the 8°C heating operation while the air conditioner is stopped
Start
a 8°C button
Press this button to start the 8°C set temperature heating operation.
• The OPERATION indicator (green) on the display panel of the indoor unit turns on.
Operation starts after approximately 3 minutes.
Stop
button
Press this button to stop the air conditioner.
If the 8°C heating operation starts while the air conditioner is stopped, press the 8°C button again to stop the operation.
Starting the 8°C heating operation while the air conditioner is operating
Start
a 8°C button
Press this button to change to the 8°C set temperature heating operation.
• If the air conditioner performs a cooling (including automatic cooling) or dry operation, it stops and the 8°C set temperature heating
operation starts after approximately 3 minutes. If the air conditioner performs a heating operation, it changes immediately to the 8°C
heating operation.
• If the air conditioner performs a PURE operation, it performs both the pure operation and 8°C heating.
Stop
button
Press this button to stop the air conditioner.
If the 8°C heating operation starts while the air conditioner is operating, press the 8°C button again to return to the previous operating
condition.
Check the operating condition on the screen of the remote control.
When a heating operation starts from 8°C heating, it can take approximately 5 minutes for the warm air to start blowing.
8°C OPERATION (RAS-***-ND model only)
CAUTION
The heating performance could worsen if the louver direction is too high during 8°C heating operation.
NOTE
• The fan speed at the start of 8°C heating is operated with AUTO.
• If a timer operation is set to before the 8°C heating operation, the timer operation setting is cancelled. Timer operation
settings cannot be made during 8°C heating operation.
• Settings for SWING (louver swing), FIX (louver position), FAN (fan speed) and PURE (pure operation) can be changed
during 8°C heating operation. Setting changes cannot be made with other buttons.
• Temperature can be changed from 5°C to 13°C during 8°C heating operation.
• The temperature of the blown air is lower than during normal heating operation.
a