Toshiba R410A Air Conditioner User Manual


 
85
Concealed Duct type
Zeolite-3G Deodorant Filter Installation Manual
Model: TCB-FPC11BE
TCB-FPC21BE
TCB-FPC31BE
TCB-FPC41BE
NOTES
Do not unpack the filter until you use it.
(Otherwise, life of the Zeolite-3G deodorant filter is shortened.)
Keep this Manual with Owners Manual of the indoor unit.
Safety Cautions
Before installation work, read thoroughly this Safety Cautions to install the air conditioner correctly.
This Safety Cautions describes the important contents concerned to the safety. Be sure to keep in mind these
items. Symbols and meanings are as described below.
WARNING
CAUTION
Indicates User may be dead or seriously injured (*1) if it is incorrectly used.
Indicates It is assumed that user may be injured (*2) or property damage (*3) may
occur if it is incorrectly used.
*1: Serious injury means a disease which has an after-effect or requires hospitalization or long-term going to the
hospital for treatment, such as loss of sight, burn (by high temperature or low temperature), electric shock,
fracture, poisoning, etc.
*2: Injury means hurt, burn, electric shock, etc. which does not require hospitalization or long-term going to the
hospital for treatment.
*3: Property damage means enlarged damage concerned to house, household effects, domestic animal, pet, etc.
Explanation of picture symbols
indicates prohibition (prohibited action).
The concrete prohibited action is indicated with picture or sentence in or near the picture symbol.
indicates that the forced instructed action (Act necessarily).
The concrete instructed action is indicated with picture or sentence in or near the picture symbol.
indicates an item with care.
The concrete item to be cautioned is indicated with picture or sentence in or near the picture symbol.
WARNING
Do not put a plastic bag including filter on a place
where hands of a small child can reach.
If the child puts the bag on his head,
it may seal his mouth or nose resulting
in choke of death.
CAUTION
Install the suction grille surely to the main unit.
If an incomplete installation is
performed, falling of the suction
grille causes an injury.
Installation of filter sold separately
1
Remove the air filter, and install a filter sold
separately to the suction port.
Push the filter sold separately completely up to the
end.
Check that the rear side is hanged to the hook.
2
Install the air filter
Be sure to fix the air filter with clamps in order to
prevent falling.
(Clamps are attached to the indoor unit.)
Maintenance of filter sold separately
Clean the filter sold separately once per 6 months.
1
Take out the filter sold separately in the
reverse order of “Installation of filter sold
separately”.
2
Cleaning of the filter sold separately
Sweep away the dust of the filter sold separately
by hitting lightly and dry it in the sunlight for 6
hours or more.
In case of wash the filter sold separately with
water
Put the filter sold separately horizontally on a
place where is exposed to the sunlight, and then
wash it with running water such as shower.
After then, leave it as it is until it will dry. In this
time, also dry it in the sunlight for 6 hours or more.
3 Install the air filter.
Based upon Installation of filter sold separately,
install the filter.
Specifications
TCB-FPC11BE TCB-FPC21BE TCB-FPC31BE TCB-FPC41BE
561BT 801BT 1101 to 1401BT
1122
70%
Approx. 12 months
Deodorant filter Model
Conformed air conditioner model name
Quantity
Initial deodorant performance
Deodorant durable performance
NOTE
If treating the filter as it gets wet, it may be damaged.
Filter sold separately
Zeolite-3G
deodorant filter
Filter sold
separately
Hook
Indoor unit
Air filter
FPBE-E