Toshiba HWS-1402H-E Heat Pump User Manual


 
117
Toshiba
12. Forced Defrosting Setting
The FC code setting (See 2-2) can activate the forced defrosting mode for the outdoor unit operation.
(Preparation)
1 Press the remote controller buttons, TEST , SET ,
and SELECT , at the same time for 4 seconds
or longer.(Make sure that no operation is in progress.)
2 Specify CODE NO. (FC) 46 with the TEMP.
button for temperature setting.
3 Set DATA to 0001 with the TIME button for timer
setting. (See display )
(Factory setting is 0000)
4 Press the SET button. (If OK lights, the status is
normal)
5 Pressing the TEST button moves the unit to the normal
stop state.
(Operation)
Press the ZONE1,2 button.
Set the operation to the heating mode.
After a while, forced defrosting signals are transmitted to the outdoor unit, and the unit starts defrosting.
(Forced defrosting lasts for up to 10 minutes.)
After the defrosting, the heating operation starts.
To perform defrosting again, start with
1 above.
(Performing the forced defrosting once cancels the forced defrosting setting above described.)
13. Rated Operation Setting
The FC code setting (See 2-2) can activate the rated operation mode during a heating operation.
(Preparation)
1 Press the remote controller buttons TEST , SET ,
and SELECT , at the same time for 4 seconds
or longer.(Make sure that no operation is in progress.)
2 Specify CODE NO. (FC) 91 with the TEMP.
button for temperature setting.
3 Set DATA to 0001 with the TIME button for timer
setting. (See display )
(Factory setting is 0000)
4 Press the SET button. (If OK lights, the status is
confirmed)
5 Pressing the TEST button moves the unit to the normal
stop state.
(Operation)
Press the ZONE1,2 button.
Set the operation to the heating mode.
After a while the outdoor unit starts an operation with the rated operation frequency.
3 horsepowers: HWS-802XWH**-E/HWS-802H-E 66.0Hz
4 horsepowers: HWS-1402XWH**-E/HWS-1102H-E 44.4Hz
5 horsepowers: HWS-1402XWH**-E/HWS-1402H-E 56.4Hz
2
3
4
1
5
2
3
4
1
5
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 117 Monday, October 5, 2009 2:09 PM