Toshiba HWS-1402H-E Heat Pump User Manual


 
114
Toshiba
8. NIGHT Operation Setting
For nighttime hours, this setting changes set temperature of heating or cooling by 5k as save operation.
1 Press the ZONE1,2 button to start a heating or a cooling
operation. (See display )
(Nighttime operation is not available for hot water supply. Use the
schedule operation.)
2 Pressing the NIGHT button displays the symbol.
A nighttime operation lowers the set temperature by 5K for heating and
raises 5K for cooling during the set time period (*1) from 22:00 to 6:00
(Default).
3 Pressing the NIGHT button again makes disappear,
and the normal operation starts.
<How to set NIGHT operation start and end time>
1 Press the NIGHT button for 4 seconds or longer.
(Moves to the NIGHT time setting mode) (See display )
"0E" in the Code No. field and the current time displayed blink.
2 Press the TIME button to set a desired start time.
Pressing SET changes the time to be lit and the setting is
confirmed.
3 Press the TEMP. button to change Code No.
(The codes "0E" and "0F" only can be changed.)
4 Press the TIME button to set a desired end time.
Pressing SET changes the time to be lit and the setting is
confirmed.
5 Press the TEST button to exit the NIGHT time setting
mode.
12,3
2,
4
3
15 1
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 114 Monday, October 5, 2009 2:09 PM