A.0500.551 – IM-TGMAG/02.00 EN (02/2008)
4.2.6 Disassembly of separation can
1. Un-tighten cap head screws (8210)
crosswise and remove them.
2. Use two cap head screws (8210) in
the threaded holes of the flange
to remove the can (8330).
3. Take out O-ring (8200).
Take care not to damage the inner rotor magnet.
Removal of rotor and bearing assembly
(back-pull-out) from the pump casing
1. Un-tighten cap head screws (8460)
and remove them.
2. Use two bolts in the threaded holes of
the intermediate cover (8450) to
remove the complete back-pull-out
assembly from the pump casing (0010).
3. Take out O-rings (8130) and (8440).
4.2.7 Disassembly of back-pull-out assembly
1. Place the back pull-out assembly on
the workbench in vertical position.
2. Un-tighten cap head screws (8490) of
the inner magnetic rotor (8310) crosswise
and remove them.
3. Remove the inner magnetic rotor (8310)
from the hub (8350-D)
Bearing set