SPX Cooling Technologies TG MAG86-100 Water Pump User Manual


 
45
2x Be Bb
Ba
A.0500.551 – IM-TGMAG/02.00 EN (02/2008)
• Foruidsthatsolidifyorbecomeveryviscous
at ambient temperature, it is best to empty
the pump immediately after shutting down
by separating it from the piping. Always wear
safety goggles and gloves.
• Protectyourselfwithaprotectivecap.The
fluid may spray out of the pump.
• OpentheventingplugsBeandBb.
• Ifnodrainlineisprovided,takeprecautions
so that the liquid is not contaminating the
environment.
• OpenthedrainplugBaatthebottomofthepumphousing.
• Letdraintheliquidbygravity.
• Purge pump spaces with flush media or cleaning liquid by connecting a purge system to the
following inlet openings:
- Ba, Be: plugs close to both flanges for purging the pump casing part
- Bb: plug on top of the intermediate cover for purging the magnetic coupling
Note: If toxic liquids were pumped special precautions regarding flushing/cleaning of the pump
and personal protection equipment must be taken before disassembling the pump.
• Re-assembletheplugsandclosethevalves,ifany.
3.21.2.9 Fluid circuits
• Depressurizethejacketsandtheretaininguidcircuits.
• Uncoupletheconnectionstothejackets.
• Ifnecessary,cleanthejacketsandthecircuitswithcompressedair.
• Avoidanyleakageofuidorthermaloilintotheenvironment.
3.21.3 Specific components
3.21.3.1 Nuts and bolts
Nuts and bolts showing damage or parts with defective threading must be removed and replaced
with parts belonging to the same fixation class as soon as possible.
• Preferablyuseatorquewrenchfortightening.
• Forthetighteningtorques,seetablebelow.
3.21.3.2 Plastic or rubber components
• Donotexposecomponentsmadeofrubberorplastic(cables,hoses,seals)totheeffectsofoils,
solvents, cleaning agents or other chemicals unless they are suitable.
• Thesecomponentsmustbereplacediftheyshowsignsofexpansion,shrinkage,hardeningor
other damage.
3.21.3.3 Flat gaskets
• Neverre-useatgaskets.
• Alwaysreplacetheatgasketsandelasticringsundertheplugswithgenuinespares.
Plug with edge and elastic washer
Bolt
Ma (Nm)
8.8 / A4
Plug with
edge and flat
seal
Ma (Nm)
M6 10 G 1/8 10
M8 25 G 1/4 20
M10 51 G 1/2 50
M12 87 - -
M16 215 - -