Speco Technologies SIPSD37X Home Security System User Manual


 
37X Speed Dome Camera 22/50
Group
z Function This function is that the camera memorizes the combination of
Presets, Pattern and/or Swings sequently and runs Presets, Pattern
and/or Swings repetitively. MAX. 8 sets of Group are programmable.
Each group can have MAX. 20 actions which are the combination of
Preset, Pattern and Swing. Preset speed can be set up and the repeat
number of Pattern & Swing can be set up in Group setup. Dwell time
between actions can be set up also.
Preset 1 Pattern 1 Swing 1
Dwell Time
Max 20 Entities
z Setting Groups To set Groups, enter into OSD menu.
z Running Groups
Method 1) <Run Pattern> [Group NO. + 20]
Method 2) <Go Preset> [Group NO. + 150]
ex) Run Group 7 : <Run Pattern>
[27]
ex) Run Group 7 : <Go Preset> [157]
z Deleting Groups To delete Groups, enter into OSD menu.
Other Functions
z Power Up Action This setting defines a specific activity (Preset, Pattern, Swing and
Group) to be performed in the event that the power to the camera is
cycled. This function enables the user to resume, after turning on
power, the last action being executed before turning off the power.
Most of actions such as Preset, Pattern, Swing and Group are
available for this function but Jog actions are not available to resume.
z Auto Flip In case that tilt angle arrives at the top of tilt orbit(90°), zoom module
camera turns on its axis by 180° at the top of tilt orbit and moves to
opposite tilt direction (180°) to keep tracing targets.
z Parking Action This feature allows the camera to begin a specified operation after a
programmed time of inactivity. This function makes the camera
automatically run a pre-defined action if there is no command from
controller for a pre-defined time period. “Wait Time” means how
long a camera should wait for from the previous-last (most recent)
command before running the pre-defined action. It can be set to 1
second ~ 3 hours.
OPERATION 3