Sharp UP-600 Air Conditioner User Manual


 
30
4.
Specifying whether to enable or disable the system retry
function when a transmission error occurs master and satellite
You can specify whether the system retry function is disabled or enabled if the communication
between machines does not end successfully.
1.
Turn the mode switch to the PGM2 position.
2.
Select “INLINE SETTING” and press the [ENTER]
key.
The INLINE SETTING menu will open.
3.
Move the cursor to the “SYSTEM RETRY” line.
Select “DISABLE” or “ENABLE” with the [ • ] key
(toggle key) and press the [CA/AT] key.
Then, press the [CANCEL] key to return to the PGM2
mode menu.
NOTE
If the system retry function is enabled, a transmission job that has ended with an error will not
be finalized immediately. The master waits for a selection of one of the three commands
(RETRY, ABORT and IGNORE) through the keyboard. Then the master retries access to the
satellite that has caused the transmission error or terminates the access as a successful or
unsuccessful transmission depending on the selection made.
If the function is disabled, the job is terminated immediately.
The default setting is “ENABLE.”