Security Centres TS2000 Home Security System User Manual


 
TS2000
496529 Issue A 9 of 20 TS2000
Use for Network
power to NU and
REM only
Cable 6 or 8 core 7/0.2mm
Maximum length 100m between each unit.
Using8 core cable will allow the Network
power supplies to be kept separate.
NOTE
It is essential that the connectors shown are
correct and that no cross-overs occur.
Incorrect connections may damage the equipment
and or cause intermittent malfunctions.
Control
Panel
+12V
0V
Down +
Down -
Dir +
Dir -
+12V
0v
MAINS
Node or REM
Up+
UP -
Dir +
Dir-
+12V
0V
Dn +
Dn -
Node or REM
Up+
UP -
Dir +
Dir-
+12V
0V
Up+
UP -
Dir +
Dir-
+12V
0V
Dn +
Dn -
Dn +
Dn -
Continue to next unit
Connect PSU where
required
Node or REM
When using 8 core cable use
the two spare cores for non
network power supplies
If required extra PSU should
be connected like this to
ensure that the supplies are
not paralleled
Power Supply Unit
with standby battery.
12V 1.5A o/p
MAINS
NOTE:AllPSUsmusthavethesamesizebattery
+12V
0V
0V
+12V
Figure 6. TS2000 Network Connections