Security Centres TS2000 Home Security System User Manual


 
TS2000
Key Functions
Engineer Reset
1. Enter your engineer’s code default 1234, you are
now in Engineer’s Mode
2. Press 0 in quit to unset.
Loading Defaults
1. Power down panel battery and mains, close LK2
2. Power up panel battery and mains
3. Enter 1234 and open LK2
4. The panel is back to Factory Default Programming.
Bell Test/Walk Test
Please refer to page 19
Memory Default Values
WhenaCP isshippedfromthe factorythememorydata
default parameters are set to:
1. Circuits: The Type and Attributes Parameters set will
depend upon the number of circuits detected;
2. Passcodes: Engineer 1234: Master 5678: Others
unspecified;
3. Timers: Exit 25 secs: Exit Settling 5 secs: First Entry 30
secs: Second entry 30 seconds: Bell delay 5 mins:
Bell Duration20 mins: CommsDelay 1.5mins: Lights
Off5secs:Mains Off10secs: MenuTimeout30 secs:
Double Knock 10 secs.
These values will also be restored if a Factory Restart
occurs.
Control Panel Links
Fuses
496529 Issue A 13 of 20 TS2000
Link Functions
LK1 Open: Printer to monitor Network
activity
Closed: Normal; Printer normal
and responds to keypad
commands
LK2 Open: Normal; On-site restart at
power up
Closed:Factory restart at power
up
LK3 DC3 Monitor; Leave closed
JP5 Normally fitted with links
Remove and fit Engineer’s REM if
required.
JP9 Open: Novram battery isolated
Closed: Normal; Novram battery
connected
JP13 Open: Normal
Closed: Soft reset
Fuse Value Use
PSU F1 1AQB Low voltage
ac input
PSU F2 2A QB 12V external
(auxiliary)
supply
Fuseholder 1A QB Network 12V
supply
Fused terminal
Block
1A Mains input