I SECTION 3 I STEP BY STEP GUIDES TO INSTALL
Close the shut-off valve on the house main water
• I. pipe, near the water meter or pressure tank, to
turn off the water.
r-_. Shut off the gas or electric supply to the water
heater.
• 3. Open the highest and lowest water faucets in
your house to let water drain from the pipes.
Close faucets after water has drained.
Shutoff Shutofl Pressure
Valve Valve Tank
Meter Pump I'
Gas
Valve
Electrical
Panel
Take all the small parts from the parts bag and
4. lay out neatly where you can easily see and get
to them as they are needud.
NOTE: The inlet screen is not used on the clarifying
filter, and can be discarded.
SMALL PARTS BAG ITEMS
(_) INLET _'_ _NLET-OUTLET
SCREEN _ ADAPTOR (2) CLIP (2)
(-_ WASHER OR
O _J GASKET (2)
GROUND
CLAMP (2) _ I] |NLET.OUTLET
___________ TUBE (2)
TRANSFORMER
_INL_r-OUTLE¢
_ _ NUT (2)
® _ GROUNDWIRE,
_, Q= SCREWS AND NUTS
5, INSTALL INLET AND OUTLET ADAPTORS OR
SEARS BYPASS VALVE, ITEM NO. 42/65-3437.
NOTE: If you will install the bypass valve, the adap-
tors are not used. If you do not install the bypass
valve, you must use the adaptors.
am
INLET AND OUTLET ADAPTORS (Adaptors
and clips are small parts bag items.) - Push the
adaptors into the valve inlet and outlet ports
(FIG. 5 and 7) as far as they will go. Both adap-
tors are the same and fit either valve port. SNAP
THE 2 LARGE HOLDING CLIPS INTO PLACE,
FROM THE TOP DOWN AS SHOWN. BE SURE
THEY SNAP FIRMLY INTO PLACE, SO THE
ADAPTORS WILL NOT PULL OUT...GO TO
STEP 6.
INSTALLING INLET AND OUTLET
ADAPTORS OR BYPASS VALVE
Clips (2)
Adaptors
SEALS //4
PLACED tN OR
ONLY. CLIP SNAPS P/
INTO INNER GROOVES
(SEE FIG. 7)
9