I SECTION 3 I STEP BY STEP GUIDES TO INSTALL
I
ELECTRIC POWER OUTLET FOR YOUR
12. FILTER
The filter works on 24 volt, 60 Hz electric power. The
included transformer changes standard 120 volt AC
house power to 24 volts.You must plug the transformer
into a 120 volt outlet only. Be sure the outlet is always
"live" so spmeone cannot turn it off by mistake.
FASTEN THE POWER CABLE AND PLUG IN
13. THETRANSFORMER
Looking at FIG. 14, fasten the 2 power cable lugs (1
under each screw) to the transformer as shown.
Tighten both screws, then plug the transformer into
the outlet.
NOTE: When you plug in the transformer, 12:00 AM
and SU begin to flash in the face plate display.
14. SANITIZING THE WATER FILTER
Care istaken at the factory to keep your filter
clean and sanitary, Materials used to make the filter
will not infect or contaminate your water supply, and
will not cause bacteria to form and grow. However, if
sanitizing is needed, do the following.
Press and hold button [] on the face plate
a. until RCHG be-_ginsto flash in the face plate
display, starting a backwash.
After 5 to 10 minutes, press
button [] again to start fast
rinse. Wait about 1 minute, THEN TURN OFF WATER
TO THE FILTER AT THE MAIN SUPPLY VALVE.
Press button [] once more to return the valve to
service.
bll
Carefully remove the large plastic clip at the
filter valve inlet (FIG. 7, page 10) and pull the
adaptor out.
NOTE: If bypass valve, Item No. 42/65-3437 is install-
ed, or ifplumbing istoo rigidto move, also disconnect
the outlet side and move the filter away from plumbing.
Put 1 teaspoon (0.1 ounce) of calcium
C. hypochlorlte into the valve inlet as far as
possible.
NOTE: You can buy calcium hypochlorite in tablet or
granular form using trade names such as Perchloren
and HTH.
CONNECTING TRANSFORMER
Transformer
i I - r--
\_/ _ Power Cable (Hook either lead
under either transformer terminaL)
dll
e.
f.
Carefully reconnect the plumbing.
Turn on the water supply.
Open the nearest filtered water faucet untilyou
can smell chlorine, then close the faucet.
DO NOT USE WATER FOR ABOUT 45
MINUTES.
gll
After the 45 minutes, see step a to start a
backwash. The filter will complete this
backwash in about 35 minutes.
While the filter is backwashing, do step 15. Then
make the timer settings beginning on page 15.
ha
When the backwash is over, open filtered
water faucets until chlorine odor isgone, then
close.
15. TURN ON THE GAS (OR ELECTRIC)
SUPPLY TO THE WATER HEATER AND
LIGHT THE PILOT.
14.