Sanyo TS4232 Air Conditioner User Manual


 
– 29 –
SM830078
5. PERFORMANCE CHARTS
(2) High and Low Pressure
11
11
1 Indoor Unit: XS4232, TS4232 Outdoor Unit: C4232
High Pressure
High pressure characteristics versus outdoor ambient temperature and indoor temperature.
(Indoor relative humidity: 50%, Indoor fan speed: High)
230V / 208V
Low Pressure
Low pressure characteristics versus outdoor ambient temperature and indoor temperature.
(Indoor relative humidity: 50%, Indoor fan speed: High)
230V / 208V
1442_X_S
Discharge pressure (psig)
280
300
320
340
200
180
160
220
240
260
59 68 77 86 95 104
(15) (20) (25) (30) (35) (40)
Outdoor ambient temp. °F (°C)
Indoor
temp.
°F (°C)
Outdoor fan speed
Low
High
70 (21)
85 (30)
80 (27)
75 (24)
1800_X_S
Suction pressure (psig)
100
60
50
40
70
80
90
59 68 77 86 95 104
(15) (20) (25) (30) (35) (40)
Outdoor ambient temp. °F (°C)
Indoor
temp.
°F (°C)
Outdoor fan speed
Low
High
70 (21)
85 (30)
80 (27)
75 (24)