Sanyo TS4232 Air Conditioner User Manual


 
– 11 –
SM830078
(2) Major Component Specifications
(A) Indoor Unit
2. SPECIFICATIONS
MODEL No. TS4232
Source 230 - 208 V / 1 phase / 60 Hz
Remote controller (Accessory) RCS - 5PS4U
Controller P. C. B Ass'y CR - TS2432
Control circuit fuse 250 V, 3 A
Switch Ass'y SW - X363GS
Fan (Number … diameter) in. (mm) Centrifugal (4 ... 5-29/32(150))
Fan motor
Model KFG4X - 101C6P
Source 230 - 208 V / 1 phase / 60 Hz
No. of pole … r.p.m. (230 V, High) rpm 1,015
Nominal output W 100
Coil resistance BRW - WHT : 61.05 , ORG - YEL : 13.23
(Ambient temperature 68 °F) WHT - VLT : 9.955 , YEL - BLK : 19.25
VLT - ORG : 9.576 , BLK - PNK : 10.81
Safety device
Operating temperature Open °F266± 14.4
Close °F 174.2 ± 27
Run capacitor VAC, µF 440 V , 4 µF
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows … Fins per inch 3 … 14.9
Face area ft.
2
(m
2
) 3.51 (0.326)
Auto louver motor
Model No. MT8 - 3C
Auto louver motor … Rated V, W, rpm 240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77 °F) 16,430 ± 8 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE