(3) Other Component Specifications
(B) Outdoor Unit
MODEL No. CL4232
Compressor Motor Magnetic Contactor FC - 2SUL
Coil rated AC 240 V, 60 Hz
Coil resistance (at 68 °F) 350 ± 10 %
Contact rated (Main) AC 240 V, 35 A
Contact rated (Auxiliary) AC 240 V, 3 A
Power Relay HH62S
Coil rated AC 240 V, 60 Hz
Coil resistance (at 77 °F) k 17.2
Contact rated AC 220 V, 5 A
Power Transformer ATR - I35B
Rated
Primary AC 220 V, 60 Hz
Secondary 14 V, 0.2 A
Capacity 2.8 VAC
Coil resistance (at 78 °F ) WHT WHT : 482.5 , BRN BRN : 3.95
Thermal cut off temperature °F266
Thermistor (Outdoor Temp. sensor)
PBC - 41E - S4
Coil resistance k 14 °F : 23.7 , 50 °F : 9.7
23 °F : 18.8 , 68 °F : 6.5
32 °F : 15.0 , 86 °F : 4.4
41 °F : 12.1 , 104 °F : 3.1
113 °F : 2.6
DATA SUBJECT TO CHANGE WITHOUT NOTICE