Sanyo TS4232 Air Conditioner User Manual


 
– 14 –
SM830078
2. SPECIFICATIONS
(3) Other Component Specifications
(A) Indoor Unit
MODEL No. XS4232
Power Transformer ATR – I104A
Rated Primary AC 220 V, 60 Hz
Secondary 10.6 V, 0.93 A
Capacity 9.85 VAC
Coil resistance
WHT - WHT : 101 , BRN - BRN : 0.42
(Ambient temprature 77 °F)
Thermistor cut off temperature °F266
Thermistor (Coil sensor) PBC - 41E - S36
Coil resistance k 14 °F : 23.7 , 41 °F : 12.1
23 °F : 18.8 , 50 °F : 9.7
32 °F : 15.0 , 59 °F : 8.0
Thermistor (Room or coil sensor) KTEC - 35 - S6
Coil resistance k 32 °F : 16.5 , 104 °F : 2.7
41 °F : 12.8 , 113 °F : 2.2
50 °F : 10.0 , 122 °F : 1.8
68 °F : 6.3 , 131 °F : 1.5
86 °F : 4.0 ,
Drain pump WP20SL - 21
Rated AC 200 V, 14.7 W
Float switch FS - 0218 - 103
MAX Rated (Contact rated) AC 200 V, 50 W
Switch Ass'y SW - X363GS
Indicator Lamp Ass'y IND - XS3632
Synchronized Motor MT8 - 3C
DATA SUBJECT TO CHANGE WITHOUT NOTICE