5
2-4. Wind Shield for CL Model
It is recommended to use wind shields for CL model
(Fig. 5b). CL model is designed to use in low outdoor
temperature conditions.
General
When the outdoor unit is installed in a position exposed
to strong wind (like seasonal winds with low air tempera-
ture in winter), a suitable wind shield must be installed
on the outdoor unit.
This unit is designed so that the fan of the outdoor unit
runs at low speed when the air conditioner is operated at
low outdoor air temperatures. When the outdoor unit is
exposed to strong wind, the system pressure drops
because of the freeze protector.
For outer dimensions of the wind shield, see Fig. 5c.
IMPORTANT
Wind shield
(air discharge side)
Front
3 - φ1-9/16" hole
6 - φ15/64" hole
9-27/32"21-5/8"15/16"
5-3/16"
22-7/16"1/2"
23-15/32"
21-13/16"
5-5/32"9-27/32"9-27/32"1-1/16"
21-13/16"
Fig. 5b
Fig. 5c
CL2462R
Recommended outer dimensions of wind shield
(field supply)