Checking and Testing Operations
Supply the power and switch on the air conditioner.
1
Press Test button more than 3 seconds without selecting any mode.
Result
: The air conditioner runs in COOL mode for 3 minutes.
2
Check that user's option(s) and the outdoor unit operate properly.
3
Press the Swing( ) button and check that the air flow blades work
properly.
4
The air conditioner will switch it off automatically after 3 minutes.
5
Wired Remote Controller
Do not attempt to select the operating mode or to adjust the
temperature. It may switch the outdoor unit off.
NN
NN
oo
oo
tt
tt
ee
ee
If the error code is displayed, fix the error referring to page 66.
And supply the power, restart testing.
NN
NN
oo
oo
tt
tt
ee
ee
To complete the installation, perform the following checks and tests to
ensure that the air conditioner is operating correctly.
Review all the following elements in the installation:
◆ Piping connection tightness to detect any gas leakages
◆ Connecting wiring
◆ Heat-resistant insulation of the piping
◆ Drainage
◆ Earthing wire connection
◆ Correct operations(follow the steps below)
If the air conditioner does not work because of switching off the
thermistor sensor caused by the room temperature,
you can operate the air conditioner by using Test button.
NN
NN
oo
oo
tt
tt
ee
ee
E-
64