Roberts Gorden CTU 22 TO 115 Gas Heater User Manual


 
SECTION 16: REMOVAL AND REPLACEMENT PARTS
41
Use only genuine ROBERTS GORDON
®
replacement parts.
The three speed winding connections are:
Low speed: White N, Red Live The other two
windings are "parked" separately in spare terminals.
Medium speed: White N, Blue live. The other two
windings are "parked" separately in spare terminals.
High speed: White N, Black live. The other two
windings are "parked" separately in spare terminals.
Check that the fan blades are free to rotate
without catching before turning on the power to
the fan.
Set all fans to operate at the same speed.
Figure 14: Centrifugal Fan Orientation
CTUB/C 22-40 CTUB/C 50-90 CTUB/C 100-115
16.9 Fan Data
MODEL CTU-22 CTU-30 CTU-40 CTU-50 CTU-60 CTU-75 CTU-90 CTU-100 CTU-115
Axial Fan Type
CTUA Models
EBM
S4E420
AA06-02
EBM
S4E420
AA06-02
EBM
S4E420
AA06-02
Ma-Vib
V02-C100
Ma-Vib
V02-C100
EBM
S4E420
AA06-02
EBM
S4E420
AA06-02
Ma-Vib
V02-C100
Ma-Vib
V02-C100
RG P/N
90710418 90710418 90710418 90710419 90710419 90710418 90710418 90710419 90710419
Quantity 1 1 1 1 1 2 2 2 2
Fan Rating
(Watts per Fan)
160 160 160 370 370 160 160 370 370
Centrifugal Fan Type
CTUB/C Models
Tor in
241-241
Tor in
241-241
Tor in
241-241
Tor in
241-241
Tor in
241-241
Tor in
270-270
Tor in
270-270
Tor in
270-270
Tor in
270-270
RG P/N A049 A049 A049 A049 A049 A047 A047 A047 A047
Quantity 1 1 1 2 2 2 2 3 3
Normal Fan Rating (W) 110 0 110 0 110 0 1100 1100 1200 1200 1200 1200
High Fan Rating (W) 1400 1400 1400 1400 1400 1700 1700 1700 1700