32
FIGURE 19: Flag Layout FIGURE 20: Modified In-Series Layout
Last Tee
Manifold tube
between joining
tee and pump.
Manifold tube
between radiant
tube ends.
Burner furthest from pump
does not need a damper coupling.
First Tee
Burner
Pump
Multiple rows of burners:
pump placed at the end of the manifold tube.
Last Tee
Pump
First Tee
Burner
Multiple burners:
pump placed at the end of the manifold tube.
A variation on the flag layout.