POSITIONING THE FLUE TERMINAL
O
H
N
N
M
Q
M
H
K
B
P
Q
Q
I
F
L
J
G
C
A
I
D,E
Dimension
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
Terminal Position
Directly below an opening, air brick, opening windows, etc.
Above an opening, air brick, opening window, etc.
Horizontally to an opening, air brick, opening window, etc.
Below gutters, soil pipes or drain pipes.
Below eaves.
Below balconies or car port roof.
From a vertical drain pipe or soil pipe.
From an internal or external corner.
Above ground, roof or balcony level.
From a surface facing the terminal.
From a terminal facing a terminal.
From an opening in a car port. (e.g. door, window) into a dwelling.
Vertically from a terminal on the same wall.
Horizontally from a terminal on the same wall.
From the wall on which the terminal is mounted
From a vertical structure on the roof.
Above an intersection with roof.
Distance
300mm
300mm
300mm
75mm
200mm
200mm
150mm
200mm
300mm
600mm
1200mm
1200mm
1500mm
300mm
N/A
N/A
N/A