Rinnai RHFE-308 FTR Fan User Manual


 
23
INSTALLATION INSTRUCTIONS
Specification
Input: 3.4kW Burner: Stainless Steel Bunsen Type
Ignition: Continuous Spark Gas Inlet: 1/2 in. BSP
Flue: Forced Flue (Components supplied separately.)
Gas Control: Rinnai Electronic Modulating Control
Electrical Supply: 230V, 50Hz. This unit has a supply lead and 3 pin plug.
Remove parts from carton and check that all parts shown below are included in the installation kit.
Back Spacer
Set
Wall Bracket
Customers Installation and
Operating Instructions
M4 for Back
Spacer Set
M4 for Air
Intake Clip
Spacer
Bracket
Flue Locking
Clamp
Insulation
Clip
Plastic Tie
for air inlet
Hose Clip
M4 for
Securing
Flue
M4.8 32
wood screws
for wall
bracket and
flue manifold.
1
1
1
1
10
2
1
1
2
1
3
5
Check the unit supplied is correct for the gas type in your area.
Refer to local gas authority for confirmation of gas type if in doubt.
Refer to data plate located inside the front panel.
Check for damage, if the unit is damaged contact your supplier of Rinnai UK.
Do not install a damaged unit before checking with your supplier.
Refer to an approved pipe sizing chart if in doubt about size of gas pipe.