4 Regency U38 ULTIMATE Freestanding Gas Stove
This is a copy of the label that accompanies
each ULTIMATE Freestanding Gas Stove. We
have printed a copy of the contents here for
your review. The safety label is located on the
inside of the drop down pedestal door.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.
SAFETY LABEL
Copy of the Safety Label for the U38 Freestanding Gas Stove
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
Minimum Clearances
to Combustibles
Degagement
minimum des
materiaux
combustibles:
222
Serial No./No de serie
DO NOT REMOVE THIS LABEL/NE
PAS ENLEVER CETTE ÉTIQUETTE
Made in CANADA / FABRIQUE AU CANADA
FPI Fireplace Products International Ltd., Delta, BC, Canada 918-029 rev. 10/03
GAS FIRED VENTED ROOM HEATER
This appliance must be installed in accordance with
local codes, if any; If not, follow: ANSI Z223.1/CAN/
CGA-B149 Electrical Supply (115 V, 1.13 A, 60 Hz)
Not for use with solid fuel.
POLE R GAZ RADIATEUR VENTILE
Cet appareil doit être installé conformement aux exigences des
codes locaux, s'il n'existe aucun code local, se conformer à la norme:
ANSI Z223.1 / CAN 1-B149 en vigueur. Alimentation électrique. Ne doit
pas être utilisé avec un combustible solide.
A 7-1/2" /190mm
B 6" /155mm
E 2" /50mm
Min. Ceiling Height
from top of unit / Min.
Plafond Hauteur en
haut de l'appareil:
36" / 914 mm
FACTORY EQUIPPED FOR NATURAL GAS: Model U38-NG
Minimum supply pressure 5" WC/C.E. (1.25kPa)
Manifold pressure High 3.8" WC/C.E. (0.94kPa)
Manifold pressure Low 1.1" WC/C.E. (0.27kPa)
Model U38-NG: Factory Equipped for Altitude 0-2000 ft.
Orifice size #31 DMS
Altitude 0-2000 ft/pi (0-610)
Maximum Input 40,000 Btu/h (11.73Kwh)
Minimum Input 21,000 Btu/h (6.15Kwh)
Model U38-NG: Convertible for Altitude 2000-4500 ft.
Orifice size #33 DMS
Altitude 2000-4500ft/pi (610-1370m)
Maximum Input 36,000 Btu/h (10.55Kw)
Minimum Input 19,000 Btu/h (5.57Kwh)
Model U38-NG: Convertible to 30,000 Btu for Altitude 0-4500 ft.
Orifice size #37 DMS
Maximum Input 30,000 Btu/h (8.78Kwh)
Minimum Input 15,000 Btu/h (4.39Kwh)
FACTORY EQUIPPED FOR PROPANE GAS: Model U38-LP
Minimum supply pressure 12" WC/C.E. (3.00Kpa)
Manifold pressure High 11" WC/C.E. (2.74Kpa)
Manifold pressure Low 2.9" WC/C.E. (0.72Kpa)
Orifice size 50 DMS
Altitude 0-2,000ft/pi (0-610m)
Maximum Input 38,000 BTU/h (11.14Kw/h)
Minimum Input 20,000 BTU/h (5.86Kw/h)
Model U38-LP: Convertible to 30,000 Btu for Altitude 0-4500 ft.
Orifice size #52 DMS
Maximum Input 30,000 Btu/h (8.78Kwh)
Minimum Input 15,000 Btu/h (4.39Kwh)
ÉQUIPÉ À L'UISINE POUR GAZ NATUREL:
Pression d’alimentation minimum
Pression tubulure d’échappement élevée
Pression tubulure d’échappement basse
Dimensions de l’orifice
L'altitude
Débit calorifique maximum selon
Débit calorifique minimum selon
Transforme en haute l'altitude Gaz Naturel:
Dimensions de l’orifice
L'altitude
Débit calorifique maximum selon
Débit calorifique minimum selon
Dimensions de l’orifice
Débit calorifique maximum selon
Débit calorifique minimum selon
ÉQUIPÉ À L'UISINE POUR GAZ PROPANE:
Pression d’alimentation minimum
Pression tubulure d’échappement élevée
Pression tubulure d’échappement basse
Dimensions de l’orifice
L’altitude
Débit calorifique maximum selon
Débit calorifique minimum selon
Dimensions de l’orifice
Débit calorifique maximum selon
Débit calorifique minimum selon
Listed: GAS FIRED VENTED ROOM HEATER
Tested to: CGA 2.17-M91, ANSI Z21.88-1998/
CSA 2.33-M98
Certified for/Certifiée pour: CANADA and USA
Report No. 476-1846-00 (Oct. 2000)
Model/Modele: U38-NG
Model/Modele: U38-LP