Regency Wraps U38-NG Stove User Manual


 
10 Regency U38 ULTIMATE Freestanding Gas Stove
LOG SET
INSTALLATION
Read the instructions below carefully
and refer to the diagrams. If logs are
broken do not use the unit until they are
replaced. Broken logs can interfere with
the pilot operation.
The gas log kit contains the following:
a) 02-65 Rear Log 902-267
b) 02-56 Middle Left Log 902-230
c) 02-44 Front Left Log 902-228
d) 02-46 Left Top Log 902-231
e) 02-45 Front Right Log 902-229
f) 02-47 Center Log 902-232
g) 02-48 Middle Right Log 902-226
h) Embers 902-151
i) Lava 902-154
Note: Install Optional Brick Panels prior
to installing logs.
Embers. Embers
The "02" refer numbers (i.e. 02-65) are
molded into the rear of each log.
1) Carefully remove the logs from the box and
unwrap them. The logs are fragile, handle
with care - do not force into position.
2) Sprinkle the embers on the left and right
sides of the firebox base.
CONVERSION TO LOWER BTU RATING FOR U38
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS
FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Natural Gas Conversion Kit 730-920
Contains:
Qty. Part # Description
1 904-240 Burner Orifice #37 (Natural Gas)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction Sheet
Propane Conversion Kit 730-922
Contains:
Qty. Part # Description
1 904-390 Burner Orifice #52 (Propane)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction Sheet
1) Shut off the gas supply.
2) Open the front door. Carefully remove the
logs and lava rock.
3) Remove burner. See diagram below.
Burner Orifice
Note: Use a
magnetic type
screwdriver if possible.
Move Rear Log
Pins forward to
front holes.
Vent Restrictor setting at High 40,000 Btu/h
Vent Restrictor setting at Low 30,000 Btu/h
INSTALLATION
4) Unscrew the 2 Rear
Log Pins and move
to the front hole
position.
5) Remove Rear Log
Bracket and slide
the Log Bracket Re-
strictor between
the Rear Log Brack-
et and the burner,
secure with the 2
screws.
7) Reinstall new burner orifice (NG stamped
#37 or LP stamped #52) and tighten.
8) Reverse steps 3) and 2).
9) Adjust Vent restrictor setting: To set the
Vent restriction as indicated in the diagram,
simply loosen the screws and push the vent
restrictor plate to the correct position. Tight-
en the screws.
Unit Btu/h Restrictor Opening
U38 40,000 A 1-3/8" (35mm)
U38 30,000 B 1-1/8" (29mm)
6) Remove burner orifice with a 1/2" wrench
and discard.
10) Attach the label "This unit has been convert-
ed to..." on top of the Serial # decal over the
higher Btu information.
11) Check for gas leaks.
12) Check inlet and outlet pressures.
13) Check operation of flame control. Check for
proper flame appearance and glow on logs.