Regency Wraps P36-NG4 Indoor Fireplace User Manual


 
Regency
®
P36-4 Gas Log Fireplace 13
INSTALLATION
FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS
SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and
REGENCY
®
DIRECT VENT SYSTEM (FLEX)
(LPG & NG)
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90
o
elbow (two 45
o
elbows equal
one 90
o
elbow).
Note: Must use optional ue adapter (Part # 510-994) when using Simpson Dura-Vent pipe.
Simpson Dura-Vent
4" (102mm) inner diameter
6-5/8" (168mm) outer diameter
Regency
®
Flex Vent
4" (102mm) inner diameter
6-7/8" (175mm) outer diameter
Maintain clearances to combustibles as listed in section "Clearances."
Horizontal fl ue must be supported every 3 feet (0.9 meters).
Firestops are required at each fl oor level and whenever passing through a wall.
A fl ue guard should be used whenever
the termination is lower than the
specifi ed minimum or as per local
codes.
Note: Regency
®
Co Axial Flue System
(Flex) is only approved for
horizontal terminations.