Regency U37-NG1 Indoor Fireplace User Manual


 
4 U37-1 Regency
®
ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove
This is a copy of the label that accompanies
each ULTIMATE Rear Vent Direct Vent Free-
standing Gas Stove. We have printed a copy
of the contents here for your review. The safety
label is located on the inside of the drop down
pedestal door.
SAFETY LABEL
NOTE: Regency
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
Copy of Safety Label for U37
DOOR SEAL ADJUSTMENT:
Please check that door is properly sealed.
Periodic adjustment of latch may be required.
FPI Fireplace Products International Ltd., Delta, BC, Canada MADE IN CANADA / FABRIQUE AU CANADA
A 7-1/2" /190 mm
B 3" /76 mm
E 4-1/2" /114 mm
Min. Ceiling
Height from top of
unit / Min. Plafond
Hauteur en haut
de l'appareil:
36" / 914 mm
Minimum Clearances
to Combustibles/
Degagement Minimum
Des Materiaux
Combustibles
Serial No./No de serie
VENTING: Only for direct discharge without duct connection. This appliance must be installed in accordance
with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI
Z223.1 in the USA or the current CAN/CGA-B149 in Canada. For Manufactured Home Installation: This Direct
Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and
Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for
Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and
with CAN/CSA Z240 MH Mobile Home Standard in Canada.
Electrical supply 115VAC, 1.13 A, 60 Hz. Not for use with solid fuel.
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
Model/Modele:
U37-NG1
Listed: GRAVITY DIRECT VENT WALL FURNACE
Certifi ed for/Certifi ée pour: CANADA AND U.S.A.
Tested to: CGA 2-17-M91, ANSI Z21.88b-2003/CSA 2.33b-2003
REPORT NO. 476-1846-00 (Oct. 2000)
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
FACTORY EQUIPPED FOR NATURAL GAS: Model U37-NG1
Min. supply pressure 5.0" WC/C.E. (1.24Kpa)
Manifold pressure High 3.8" WC/C.E. (0.947Kpa)
Manifold pressure Low 1.1" WC/C.E. (0.27Kpa)
Orifi ce size #37 DMS
Altitude 0-4500 ft/pi (0-1370m)
Maximum Input 30,000 Btu/h (8.79Kw/h)
Minimum Input 15,000 Btu/h (4.39Kw/h)
ÉQUIPÉ À L'UISINE POUR GAZ NATURAL:
ÉQUIPÉ À L'UISINE POUR GAZ PROPANE:
Pression d’alimentation minimum
Pression à la tubulure d’échappement élevée
Pression à la tubulure d’échappement élevée
Dimensions de l’orifi ce
L’altitude
Débit calorifi que maximum selon
Débit calorifi que minimum selon
918-507
Model/Modele:
U37-LP1
313
FACTORY EQUIPPED FOR PROPANE: Model U37-LP1
Min. supply pressure 12" WC/C.E. (3.00Kpa)
Manifold pressure High 11" WC/C.E. (2.74Kpa)
Manifold pressure Low 2.9" WC/C.E. (0.72Kpa)
Orifi ce size #52 DMS
Altitude 0-4500 ft/pi (0-1370m)
Maximum Input 30,000 Btu/h (8.79Kw/h)
Minimum Input 15,000 Btu/h (4.39Kw/h)
Pression d’alimentation minimum
Pression à la tubulure d’échappement élevée
Pression à la tubulure d’échappement élevée
Dimensions de l’orifi ce
L’altitude
Débit calorifi que maximum selon
Débit calorifi que minimum selon
For the State of Massachusetts, installation and repair must be
done by a plumber or gasfi tter licensed in the Commonwealth
of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not
exceed 36 inches in length.
For the State of Massachusetts, the appliances individual
manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a
carbon monoxide alarm in accordance with NFPA 720 and a
CO alarm with battery back up in the same room where the
gas appliance is installed.