Regency U37-NG1 Indoor Fireplace User Manual


 
U37-1 Regency
®
ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove 17
CONVERSION KIT# 514-969 FROM NG TO LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one LPG
Conversion Kit and one DC
Sparker Kit.
Conversion Kit Contains:
Qty. Part # Description
1 904-390 Burner Orifi ce #52
1 904-529 5/32" Allen Key
1 918-590 Decal "Converted
to LPG"
1 908-528 Red "LPG" label
1 910-037 LPG Injector
(Pilot Orifi ce)
1 918-481 Instruction Sheet
DC Sparker Kit Contains:
Qty. Part # Description
1 820-475 Bracket DC Sparker
1 820-476 Bracket DC Sparker
1 904-153 Washer #8 External Star
1 904-330 Nut 8-32 Hex
1 904-438 Plug Nylon 0.750 Hole,
Black
2 904-531 Bushing Split Plastic
0.500 in.
1 904-543 Screw 8-32 x 3/4 Pan
Head
2 904-553 Screw #8 x 1/2 Type "B",
Black Oxide
1 910-073 Spark Generator Battery
Holder
1 910-074 Spark Generator Switch
C/W Wire
1 910-078 Battery Size AA
Energizer En91
2 910-199 Clip Wire Holder
1 910-903 Wire Fan To Power Cord
Ground 30 in.
904-781 Velcro Hook, Black
904-782 Velcro Hook, Black
Installation of LPG
Conversion Kit:
1) Shut off the gas supply.
2) Open the front door and carefully re-
move the logs and lava rock.
3) Remove burner. See diagram below.
Note:
Use a magnetic type screwdriver if possible.
Pilot assembly is now accessible.
4) Pull off the pilot cap to expose the pilot
orifi ce.
5) Unscrew the pilot orifi ce with the allen
key; then replace with the LPG pilot
orifi ce and the pilot cap, provided in the
kit.
6) Remove burner orifi ce with a 1/2"
wrench. Use another wrench to hold on
to the elbow behind the orifi ce. Discard
orifi ce.
Burner Orifi ce
7) Reinstall new burner orifi ce LPG
stamped #52 and tighten.
8) Turn control knob to the “OFF” position.
Fig.1
9) Remove the black
protection cap by hand
from the hi-low knob
(Fig.1).
INSTALLATION