14) Verify that if the conversion is from NG
to LPG, the screw must be re-assem-
bled with the red o-ring visible (Fig. 5).
LPG Configuration
Red o-ring visible
Fig.5
15) Re-assemble the black protection cap
(Fig. 6).
Fig. 6
WARNING!
Also check that the pilot and main
burner injectors are appropriate for
the gas type.
17) Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
18) Replace yellow "NG" label with red
"LPG" label.
16) Reverse step 2).
Fi
g
.2
12) Flip the screw (Fig. 3).
Fig.4
Fig.3
13) Using the Allen wrench
as shown in Fig.4, rotate
the screw clockwise until
snug, do not overtighten.
10) Insert a 5/32” or 4mm
Allen wrench into the
hexagonal key-way
of the screw (Fig.
2), rotate it counter-
clockwise until it is free
and extract it.
11) Check that the screw is clean and if
necessary remove dirt.
WARNING!
Do not over tighten the screw.
Recommended to
grip the wrench by the short side.
Installation of the DC Sparker:
19) Remove the back pedestal cover by
unscrewing the 4 screws.
20) Remove the front control panel by
unscrewing the 6 screws.
22) Plug up the Piezo Ignitor mounting hole
with the plastic plug.
21) Unplug the Piezo Ignitor wire and
remove Piezo Ignitor from the control
panel.
23) Connect the DC spark generator wires
to the SIT Valve with the screw, which is
provided in the kit.
24) Secure with screw.
INSTALLATION