Regency L900-LP Indoor Fireplace User Manual


 
Regency
®
L900 Direct Vent Gas Fireplace
40
OPERATION
OPERATING INSTRUCTIONS
NOTE: The control knob is located on the
right hand side of the fi rebox behind the
right side exterior brick panel.
1) Push in gas control knob slightly and turn
clockwise to “OFF”. Knob cannot be turned
from “PILOT” to “OFF” unless knob is pushed
in slightly. Do not force.
2) Wait fi ve (5) minutes to clear out any gas.
3) Turn knob on gas control counterclockwise
to “PILOT”.
4) Push in control knob all the way and hold in
until the pilot lights up. Continue to hold the
control knob in for about 20 seconds after
the pilot is lit. Release knob and it will pop
back up. Pilot should remain lit. If it goes out,
repeat steps 1) to 4). If knob does not pop
up when released, stop and immediately
call your service technician or gas supplier.
If the pilot will not stay lit after several tries,
turn the gas control knob to “OFF” and call
your service technician or gas supplier.
5) Turn gas control knob counterclock-wise to
“ON”.
6) Turn the unit on with the remote.
NOTE: When using the remote control refer
to the FireWizard manual for instructions.
SHUTDOWN
PROCEDURE
1) Turn the 3-way switch to the "OFF"
position.
2) Turn the main gas control clockwise to the
"OFF" position to turn off the pilot.
3) Turn off all electric power to appliance if
service is to be performed.
NORMAL OPERATING
SOUNDS OF
GAS APPLIANCES
It is possible that you will hear some sounds
from your gas appliance. This is perfectly normal
due to the fact that there are various gauges
and types of steel used within your appliance.
Listed below are some examples. All are normal
operating sounds and should not be considered
as defects in your appliance.
Burner Tray:
The burner tray is positioned directly under the
burner tube and logs and is made of a different
gauge material from the rest of the fi rebox and
body. Therefore, the varying thicknesses of steel
will expand and contract at slightly different
rates which can cause "ticking" and "cracking"
sounds. You should also be aware that as there
are temperature changes within the unit these
sounds will likely re-occur. Again, this is normal
for steel fi reboxes.
Pilot Flame:
While the pilot fl ame is on it can make a very
slight "whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
OPERATION DURING
POWER OUTAGE
Important:
If the unit is not used for a prolonged period of
time, we recommend turning the 3-way switch on
the manual control panel to "Off" (manual control
panel is located on the left hand side of the fi rebox
behind the left side exterior brick panel).
Also see "Lighting Plate Instructions" for details
on how to turn off the pilot.
Rear Burner
Switch
3-way Switch
Manual Control Panel
Located on the left hand side of the
fi rebox behind the exterior brick panel.
When in "Remote" position;
In the event of a power failure, if the 3-way switch
is in the "Remote" position, the unit cannot be
operated with the Remote Control until after
power is restored.
To operate unit during a power failure;
NOTE: Both burners when on will operate at the
lowest fl ame setting. The BTU's for NG
will be 32,000 and 27,000 for LP.
Front Burner Operation:
1) Remove the left side exterior brick panel to
access to the Manual Control Panel.
2) To turn on the front burner, change the 3-way
switch to "Manual" position.
Rear Burner Operation:
1) Remove the left side exterior brick panel to
access to the Manual Control Panel.
2) To turn on the rear burner, change the Rear
Burner Switch to the "On" position. Changing
the switch to the "Off" postion will turn the
rear burner off.
Note: The rear burner will only operate if the
front burner is on.
When in "Manual" position;
In the event of a power failure, if the 3-way switch
is in the "Manual" position the front buner will
remain on at the lowest setting and will remain
on when power resumes. If the rear burner is
not in use, to operate see "Rear Burner Opera-
tion" above.
Both burners when on will operate at the lowest
fl ame setting. The BTU's for NG will be 32,000
and 27,000 for LP.
When power resumes the unit will remain on at
the lowest setting until reset using the remote
control.
NOTE: When power is restored, reset the
3-way switch on the Manual Control
Panel to the "Remote" position to be
able to use the FireWizard
TM
Remote
Control.