Regency L900-LP Indoor Fireplace User Manual


 
Regency
®
L900 Direct Vent Gas Fireplace 27
INSTALLATION
1) Remove the glass door.
3) Lift up and pull out the heat shield slightly
to clear the screwheads and then hang it
on the top bracket (located directly above
the heat shield).
4) Unplug the power source.
5) Loosen the bottom screw and remove the
top screw from the power module.
6) Cut the cable tie that holds together the
wires for the power module and the pull
out the power module.
7) Remove the power module cover by
removing the 2 screws, one on each side.
8) Install the 9V battery and the AA battery.
2) Loosen the 2 screws that hold the left side
heat shield in place.
BACK-UP BATTERY INSTALLATION
(within Power Module)
Power Module
Power
Module
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
b. Swing the door out from the top and release
the hinges on the left and right side of the
door by lifting them up.
Hinge
Door
Latch
Latch Location
Heat
Shield
Bracket
Heat
Shield
INSTALLATION
9) Reverse steps 7 to 1.
c. Place the door on a soft surface to prevent
scratching.
The 9V battery operates the rear burner under power outage conditions.
The AA battery operates the DC Sparker for lighting the pilot.