25) Remove the pilot shield by removing the 2
screws.
26) Remove the clip from the pilot head assembly
using a fl at head screw driver.
27) Remove the NG pilot orifi ce with the Allen
Key and replace with LP pilot orifi ce.
28) Re-install the pilot head and pilot shield.
Clip
29) Using a Torx T20, remove and discard the
3 pressure regulator mounting screws.
Remove the modulator coil and the
gasket.
30) Ensure that the new rubber gasket (supplied
with coil) is properly positioned and install the
new modulating pressure regulator assem-
bly to the valve using the screws supplied
with the kit. Tighten screws securely.
31) Install the enclosed identifi cation label to the
valve body where it can be easily seen.
32) Attach the LP conversion decal near or
on top of the serial no. decal.
33) Replace yellow "Natural Gas" label with red
"Propane" label.
34) Re-install valve tray and all electrical
connections to the valve and solenoid
valve.
35) Cut the cable tie that holds the wires
connected to the Control Module and pull
out.
Note: An extra cable tie is included with
the LP Kit for re-installation.
Cable Tie
Control Module
36) Remove the J9 jumper using needle nose
pliers.
37) Re-install the control module.
38) Re-install the base brick panel.
39) Re-install the rear log support bracket.
40) Plug in the power source.
41) Re-install the left heat shield.
42) Install the interior brick panels.
43) Adjust the burner aeration settings to the LP
settings and install the burners.
Front Burner 1/4"
Rear Burner 3/8"
44) Re-install the grate.
45) Turn on the gas supply and check for gas
leaks.
46) Install the log set.
47) Re-install the glass door.
48) Check the inlet and outlet pressures.
49) Re-install the right heat shield.
50) Check operation of fl ame control using
the remote control. Refer to FireWizard
operation manual for details.
51) Check for proper fl ame appearance.
52) Install the exterior brick panels.
Installer Notice:
This instructions must be left
with the appliance.
J9 Jumper Location
Pilot
Shield
J9 Jumper
INSTALLATION