I1200 Regency Wood Insert 19
the charcoal stage faster and burns up any
wood vapors which might otherwise be
deposited within the system.
3) Only burn seasoned wood! Avoid burning
wet or green wood. Seasoned wood has
been dried at least one year.
4) A small hot fi re is preferable to a large
smouldering one that can deposit creosote
within the system.
5) Check the chimney at least twice a month
during the burning season for creosote
build-up.
6) Have chimney system and unit cleaned by
competent chimney sweeps twice a year
during the fi rst year of use and at least once
a year thereafter or when needed.
MAINTENANCE OF
GOLD-PLATED DOORS
The gold electroplated fi nish on the doors
requires little maintenance, and need only be
cleaned with a damp cloth. DO NOT use abrasive
materials or chemical cleaners, as they may
harm the fi nish and void the warranty.
DOOR GASKET
If the door gasket requires replacement, 7/8"
diameter material must be used. A proper high
temperature gasket adhesive is required. A
gasket repair kit, Part # 846-570 is available
from your local Regency dealer.
DOOR LATCH
ADJUSTMENT
The door latch may require adjustment as the
door gasket material compresses over time.
Removal of the spacer washer, shown in the
diagram below, will allow the latch to be moved
closer to the door frame, causing a tighter
seal. Remove and replace the nuts, washer
MAINTENANCE
as shown.
GLASS CLEANING
Do not attempt to clean the glass when it is hot,
allow the glass to cool before cleaning.
Do not use abrasive cleaners to clean the glass.
Your local retailer can supply you with special
glass cleaner if plain water and a soft cloth does
not remove all deposits.
GLASS
REPLACEMENT
Your Regency Insert is supplied with 5 mm.
Neoceram ceramic glass that will withstand
the highest heat that your unit will produce. In
the event that you break your glass by impact
- purchase your replacement from an authorized
Regency dealer only, and follow our step-by-step
instructions.
GLASS REMOVAL
Allow the stove to cool before removing or replac-
ing glass. Remove the door from the insert and
remove the glass retainer. Use caution when
removing broken glass to prevent injury.
When placing the replacement glass in the
door, make sure that the glass gasketing will
properly seal your unit. Replace the retainer
and tighten securely, but do not wrench down
on the glass as this may cause breakage. Do
not substitute materials. If your glass door does
break, do not continue to use your unit until it
has been replaced.