Regency FG39-LPG Stove User Manual


 
Regency FG39 FireGenie Freestanding Gas Stove
9
INSTALLATION
FLUEING ARRANGEMENTS
Vertical Terminations Using
Dura-Flue Fluing System for
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable
combinations of straight vertical and offset to vertical runs
with vertical terminations. Maximum two 45
o
elbows.
If the flue is ENCLOSED in a chase (min. size 9" x 9" / 229mm x 229mm)
maintain a 1-1/4" (32mm) clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after first sale.
Horizontal Terminations for All Fluing Systems
The shaded areas in the diagram below show all allowable
combinations of vertical runs with horizontal terminations.
Maximum one 90
O
elbow (two 45
o
elbows equal one 90
o
elbow).
LPG and NG:
Residential, Manufactured and Mobile Homes
Installations
The fluing arrangements diagrammed below, have a min. of 75% (flue
loss) efficiency with Fan Off, as required for manufactured homes.
(Actual efficiency may be as high as 85%)
May be installed in Manufactured (Mobile) Homes after first sale.
Flue Restrictor Position
To set the Flue restriction as indicated in the diagram, simply loosen the
screws and push the flue restrictor plate to the correct position. Tighten
the screws.
Flue Restrictor setting at
40 Mj/h
Flue Restrictor setting at
31 Mj/h