Regency FG39-LPG Stove User Manual


 
12
Regency FG39 FireGenie Freestanding Gas Stove
Pipe Length
Round Support
Box/Wall Thimble
(Part # 940)
Round
Support Box/
Wall Thimble
(Part # 940)
Vertical
Terminal
Storm Collar
Part # 953
Flashing
943 or 943S
Ceiling Firestop
(Part # 963)
24" (610mm)
Pipe Length
Adj.Pipe Length
11" - 14-5/8"
(279mm - 372mm)
90 Elbow
o
Wall Thimble
Part # 942
Vinyl Siding
Standoff (Optional)
Part #950
AstroCap
Termination Cap
(Part# 946-523)
DURA-FLUE
TERMINATION KIT
Planning Your Dura-Flue
Installation
There are two basic types of Dura-Flue Room
Sealed System installations: horizontal termi-
nation and vertical termination. Confirm the
maximum horizontal run and maximum vertical
rise from the diagrams on page 9.
When planning your installation, it will be nec-
essary to select the proper length of flue pipe
for your particular requirements. For horizontal
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also
important to note the wall thickness. (The wall
thimble is suitable for 2 x 4 or 2 x 6 / .6m x 1m
or .6m x 2m wall construction.) Select the
amount of vertical rise desired for "vertical-to-
horizontal" type installations.
Warning: Always maintain required clear-
ances (air spaces) to nearby combusti-
bles to prevent a fire hazard. Do not fill air
spaces with insulation.
The minimum clearance requirements between
the outer wall of the flue pipe and nearby
combustible surfaces is 1-1/4 inch. Be sure to
check the flue termination clearance require-
ments from decks, windows, soffits, gas reg-
ulators, air supply inlets and public walkways
as specified in the Exterior Flue Termination
Locations on page 8 and in your local building
codes.
To determine the length of flue pipe required for
vertical installations, measure the distance from
the unit flue outlet to the ceiling, the ceiling
thickness, the vertical rise in an attic or second
storey, and allow for sufficient vertical height
above the roof line.
For multi-storey applications, fire stops are
required at each floor level. If an offset is
needed, additional pipe, elbows and supports
will be required.
Do not exceed the maximum number of elbows.
One 90
o
for horizontal terminations and two 45
o
for vertical termination.
DURA-FLUE FLUING
COMPONENTS
You will require the following components with
your new Regency Room Sealed Freestanding
Gas Stove. Please review your product to make
sure you have everything you need. In the eflue
that you are missing any part, contact your
dealer.
Note: These are the minimum pieces
required. Other parts may be re-
quired for your particular instal-
lation. See below for a list of flue
parts.
If installing termination on a siding covered wall,
a vinyl siding standoff or furring strips can be
used in order to ensure that the termination is not
recessed into siding.
The vinyl siding standoff is required for walls
with vinyl siding.
Minimum components for a Dura-Flue
Horizontal Installation:
A) Dura-Flue Horizontal Termination Kit
B) Wall Thimble (required for combus-
tible walls)
Minimum components for a Dura-Flue
Vertical Termination:
C) Dura-Flue Vertical Termination Kit
The Simpson Dura-Flue Room Sealed System
offers a complete line of component parts for
installation of both horizontal and vertical instal-
lation. Many items are offered in decorative
black, as well as galvanized finish. The galva-
nized pipe and fittings are used for concealed
INSTALLATION
locations such as attics or where corrosion is
a factor, such as above the roof line. Decora-
tive brass trim kits are available for both wall
thimbles and ceiling support boxes.
Part # Description
971 Horiz. Termination Kit includes: 90
o
black elbow, wall thimble cover,
horiz. square termination cap, 24"
black pipe, 11" -14" 5/8" adjustable
black pipe
970 Basic Horiz. Termination Kit
includes: 90
o
black elbow, wall
thimble cover, horiz. square
termination cap
978 Vert. Termination Kit includes
0/12 - 6/12 pitch adjustable
flashing, storm collar, low profile
term. cap
908B 6" (152mm) Pipe Length-Black
907B 9" (229mm) Pipe Length-Black
906 12" (304mm) Pipe Length Galv.
906B 12" (304mm) Pipe Length-Black
904 24" (610mm) Pipe Length Galv.
904B 24" (610mm) Pipe Length-Black
903 36" (914mm) Pipe Length Galv.
903B 36" (914mm) Pipe Length-Black
902 48" (1219mm) Pipe Length Galv.
902B 48" (1219mm) Pipe Length-Black
911B 11"-14 5/8" (219mm - 372mm)
Adj. Pipe Length-Black
917B 17"- 24" (432mm - 610mm)
Adj. Pipe Length Black
945 45
O
Elbow Galv.
945B 45
O
Elbow-Black
945G 45
O
Elbow-Swivel Galv.
990G 90
O
Elbow-Swivel Galv.
Dura-Flue Basic
Horizontal Kit # 970
190
o
Elbow
1 Wall Thimble Cover
1 Astro Cap