4 Regency
®
E21-3 Gas Fireplace Insert
SAFETY LABEL
This is a copy of the label that accompanies
each Regency
®
Gas Insert. We have printed
a copy of the contents here for your review.
The safety label is located on the front inside
base of the unit visible when the bottom louver
is open.
Note: Regency
®
units are constantly being
improved. Check the label on the unit
and if there is a difference, the label
on the unit is the correct one.
Please note that with the addition
of thermostat control and outside
combustion air supply, this unit is
approved for bedroom installations.
Listed: VENTED GAS FIREPLACE HEATER
Tested to: ANSI Z21.88a-2007/CSA-2.33a-2007, CGA 2.17-M91
Gas fi red appliance for use at high altitude.
Certifi ed for/Certifee pour: CANADA and U.S.A. WN# 16353
Model/
Modele:
DO NOT REMOVE THIS LABEL/ NE PAS ENLEVER CETTE ÉTIQUETTE
327
Serial No./
No de Serie
918-672a
Minimum Clearances to Combustibles/
Degagement Minimum Des Materiaux
Combustibles:
Side of unit to wall /
Cote:
A 9"/229mm
Top of unit to
mantle / Au dessus:
B 14"/355mm
MADE IN CANADA / FABRIQUE AU CANADA
FPI Fireplace Products International Ltd., Delta, B.C., Canada
FIREPLACE INSERT: E21-NG3 E21-LP3 APPAREIL FONCTIONNANT CONCU POUR
Natural Gas (Naturel Gaz) Propane ETRE INSERE DANS UN FOYER
Minimum supply pressure 5.0" WC/C.E. (1.25 kPa) 12.0" WC/C.E. (2.99 kPa) Pression d’alimentation minimum
Manifold pressure high 3.8" WC/C.E. (0.95 kPa) 11.0" WC/C.E. (2.74 kPa) Pression tublure d'échappement élevée
Manifold pressure low 1.1" WC/C.E. (0.27 kPa) 2.9" WC/C.E. (0.72 kPa) Pression tublure d'échappement basse
Altitude 0-2000 ft. 2000 - 4500 ft. 0-4500 ft. L'altitude
(0 - 610m) (610 - 1372m) (0-1372m)
Orifi ce size 43 DMS 44 DMS 54 DMS Grandeur de l’injecteur
Maximum input 23,500 Btu/h 22,000 Btu/h 22,500 Btu/h Debit calorifi que maximum
Minimum input 11,750 Btu/h 11,000 Btu/h 11,250 Btu/h Debit calorifi que minimum
Duplicate Serial No.
NOT FOR USE WITH SOLID FUEL. NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
For installation into a vented non-combustible
fi replace, listed factory built fi replace. This vented
gas fi replace heater is not for use with air fi lters.
Ne peut etre installe que dans un foyer non
combustible muni d'un event. Ne pas utiliser de
fi ltre à air avec ce foyer au gaz à évacuation.
WARNING: This fi replace has been converted for use
with a gas fi replace insert only and cannot be used for
burning wood or solid fuels unless all original parts
have been replaced, and the fi replace re-approved by
the authority having jurisdiction.
ELECTRICAL SUPPLY/ALIMENTATION
ELECTRIQUE:115V60HZ less than/Moins de 2 AMP.
E21-NG3
E21-LP3
327
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.