Regency E21-NG3 Indoor Fireplace User Manual


 
11Regency
®
E21-3 Gas Fireplace Insert
Note: Do not operate unit if ue connector is not
fastened in original position.
FLUE CONNECTOR INSTALLATION
1) Remove the screw holding the ue connector
plate to the appliance.
2) Slide the plate out and attach to the ue liner
inside the replace to the ue collar with three
sheet metal screws.
3) Place the appliance on the hearth. Push
the appliance into the replace and at the
same time slide the plate back onto the ap-
pliance.
4) Replace the screw holding the plate just
before completely pushing the appliance into
the replace.
INSTALLATION
For PROPANE Units and Units Equipped with DC Spark Boxes*
*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.