Regency C34-NG2 Stove User Manual


 
28 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater
OPERATING INSTRUCTIONS
OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the ap-
pliance with the glass removed.
5) Verify that the venting is unobstructed.
6) Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs have
been incorrectly positioned.
7) The unit should never be turned off, and on
again without a minimum of a 60 second
wait for purging.
Note: Clean fingerprints off the gold
before lighting stove.
3) Turn gas control knob counterclockwise so
indicator points to the "PILOT" position. De-
press the gas control knob fully. Depress
the igniter button several times until the pilot
lights. After approximately one minute, re-
lease the gas control knob. The pilot flame
should continue to burn. If the pilot does not
remain lit, repeat operation allowing a longer
period before releasing gas control knob.
4) When the pilot stays lit, turn the gas knob
further counterclockwise to the "ON" posi-
tion.
5) Use the ON/OFF switch, wall switch, ther-
mostat or remote control to turn on the unit.
6) Rotate the flame height regulator (Hi/Lo) to
adjust the flame height higher or lower.
SHUTDOWN
PROCEDURE
1) Use the ON/OFF switch, wall switch, ther-
mostat or remote control to turn off the
burner.
2) Push in the PILOT knob slightly and turn
clockwise to off. Do not force.
3) Turn off all electric power to the appliance
if service is to be performed.
FIRST FIRE
The first fire in your stove is part of the paint
curing process. To ensure that the paint is
properly cured, it is recommended that you burn
your fireplace for at least four (4) hours the first
time you use it with the fan on. When first
operated, the unit will release an odour caused
by the curing of the paint, the burning off of any
oils remaining from manufacturing. Smoke de-
tectors in the house may go off at this time. Open
a few windows to ventilate the room for a
couple of hours.
The glass panel may require cleaning after the
unit has cooled down. DO NOT ATTEMPT TO
CLEAN THE GLASS WHILE IT IS HOT.
Note: When the glass is cold and the
appliance is lit, it may cause con-
densation and fog the glass. This
condensation is normal and will
disappear in a few minutes as the
glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
During the first few fires, a white film
may develop on the glass front as part
of the curing process. The glass
should be cleaned or the film will bake
on and become very difficult to re-
move. Use a non-abrasive cleaner and
NEVER clean the glass while it is hot.
LIGHTING
PROCEDURE
IMPORTANT: Gas cock knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.
1) Turn burner OFF using "ON/OFF" switch.
2) Turn gas control knob so indicator points to
"OFF" position and allow 5 minutes for any
gas in the combustion chamber to escape.
Incorrect flame pattern will have small,
probably yellow flames, not coming into
proper contact with the rear burner or
thermopile or thermocouple.
PILOT ADJUSTMENT
Periodically check the pilot flames. Correct
flame pattern has three strong blue flames: 1
flowing around the thermopile, 1 around the
thermocouple and 1 flowing across the burner
(it does not have to be touching the burner).
Note: If you have an incorrect flame
pattern, contact your Regency
dealer for further instructions.
Top View of pilot flame
Top View of pilot flame
IMPORTANT
To ignite or reignite the pilot,
remove one glass panel/door.
Only when the pilot holds, without pressure
being applied to the control knob, resecure
the glass panel to the unit. The unit must not
be operated with the glass removed.