Regency C34-NG2 Stove User Manual


 
14 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater
Horizontal Venting with Two (2) 90
o
Elbows
Option V H + H1
A) 4' Min. 6' Max.
B) 5' Min. 7' Max.
C) 6' Min. 8' Max.
Vertical Venting with Two (2) 90
o
Elbows
Option V H V + V1
A) 1' Min. 4' Max. 2' Min.
B) 2' Min. 5' Max. 3' Min.
C) 3' Min. 6' Max. 4' Min.
D) 4' Min. 7' Max. 5' Min.
E) 5' Min. 8' Max. 6' Min.
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is re-
quired.
With these options, maximum total
pipe length is 30 feet with minimum
of 6 feet total vertical and maximum
8 feet total horizontal.
Please note minimum 1 foot
between 90
o
elbows is required.
INSTALLATION
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
Vent restrictor position C (fully
open), refer to page 9.
Vent restrictor position C (fully open), refer to page 9.
Lengths do not include elbow
indicated.
Lengths do not include elbow indicated.