Regency 946-523/P Indoor Fireplace User Manual


 
Flex Liner
Exhaust
Flue
A maximum
of two certified
joiner kits
may be used
per length.
#948-305
35 ft (11m)
Air Intake
Co-linear DV
Vertical Termination
Cap # 946-529
Co-Linea
Flex
Adapter
with Kit#
946-563
Outer
Pipe
with Kit#
946-563
Inner Pipe
Adapter
with Kit#
946-563
Rigid Pipe Adapter
# 510-994
Pipe Length
45 Elbow
o
Vertical termination with co-linear
ex system
The appliance must not be connected to a chimney ue
serving a separate solid fuel burning appliance.
Masonry chimneys may take various contours which the exible liner
will accommodate. However, keep the exible liner as straight as
possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the
termination cap.
This appliance is designed to be attached to two 3” (76mm) co-linear
aluminium ex running the full length of the chimney. See the Venting
Arrangements for minimum and maximum heights.
Required Parts:
Part # Description
946-529 Co-linear DV Vertical Termination Cap
948-305 3” Flex - 35 ft.
946-563 Coaxial to Co-linear Adapter Kit
510-994 Rigid Pipe Adapter
58dva-E45 45º Elbow
Alternate Approved Caps
46dva-VC Vertical Termination Cap
46dva-VCH High Wind Cap
46dva-GK
3” Co-linear Adapter with ashing
The shaded area in the diagrams show the allowable vertical
terminations.
8' (2.4m) Min.
30”
(762mm)
30' (9.1m) Max.
30
Horizontal Distance (Feet)
Vertical Height (feet)
2’ (51mm) max.
Please refer to Exterior Vent Terminations for
additional guidelines on vent locations.
P33 Gas Fireplace
37August 2008 Product Speci cations Book
Gas Fireplaces