General Operating Guidelines and Limitations
StorNext User’s Guide 347
All As a result of log rolling changes in StorNext 3.0, logs are now rolled every 6
hours. For each log, 28 instances (7 days of logs) are retained. Log instances
are retained in the same directory as the original log.
All log files which are rolled are affected by this change, including TSM logs
(t
ac_00, bp_*.log, hist_01, etc.), MSM logs (tac_00, hist_01, etc.), and any other
components configured for rolling. The
<component>/config/filelist file
contains
roll_log entries that determine which files are rolled (where
<component> is /usr/adic/TSM, /usr/adic/MSM/, etc.).
The StorNext Library Space Used Report (accessible from the StorNext home
page by choosing Library Space from the Reports menu,) shows the amount
of nearline space used.
The nearline space amount does not include dead space, but does include the
following:
• All used space on all media in all libraries except vaults
• All space used by files that were put on a storage disk or de-duplicated
storage disk
The StorNext GUI does not support an isolated metadata network topology
with a system configured for HA failover. If the browser does not have
connectivity to the isolated metadata network, then it will fail to connect after
a failover event. If you have an isolated metadata network topology, make
sure the browser has connectivity to the isolated metadata network or correct
the network topology so the browser has connectivity to the isolated
metadata network.
For more information, contact Quantum Global Services.
Operating System /