Quadra-Fire MTVERNINSAE-MBK Stove User Manual


 
Page 42
7036-135G
November 22, 2011
R
Mt. Vernon Pellet Insert (AE)
Convection Blower Replacement
G. Convection Blower Replacement (Cont’d)
1. After the sides are removed, r
each behind the blower
and release the latch by pushing the top of the latch
towards the blower. Figure 42.1.
2. Rock the top of the blower slightly and lift up and out.
The blower will pass around the control board and out
the side of the appliance.
3. Disconnect the wire harness from the bottom of the
blower by depressing the tabs on the sides of the con-
nector and then pulling to remove. Figure 42.2.
4. Re-connect wire harness to the new replacement
blower. Install the blower by placing the bottom fl ange
into the opening fi rst then rotate blower up into posi-
tion.
5.
When the blower is properly positioned the latch will engage
the notch to hold the blower in place. Figure 42.3.
Convection
Blower
Disconnect Wire Harness
from Bottom of Blower
Notch
Latch
Latch Engaged
Figure 42.2
Figure 42.1
Figure 42.3