Quadra-Fire MTVERNINSAE-MBK Stove User Manual


 
R
November 22, 2011
7036-135G
Page 41
Mt. Vernon Pellet Insert (AE)
F. Glass Replacement
Glass is 5mm thick high temperature heat-re-
sistant ceramic glass.
DO NOT REPLACE with any other material.
Alternate material may shatter and cause
injury
WARNING
Figure 41.1
a. Swing open the face and remove door from the appli-
ance by lifting door off of hinge pins and lay on a fl at
surface face down.
b. Using a Phillips head screw driver, remove 4 screws 2
on the top and 2 on the bottom. Remove metal bracket
and then remove the glass. Figure 41.1.
c. Replace with new glass with gasket.
d. Re-attached metal bracket with 4 screws.
e. Re-install door over hinge pins and close face.
Remove 4 screws
Glass with Gasket
Metal Bracket
G. Convection Blower Replacement
Location of Latch for
Removing Cast Sides
Removal of Cast Sides
You will need to remove the cast sides in order to remove
and replace the convection blower.
1. There is a latch on the back side of the cast side in the
middle of the top opening of the cast side as indicated
in Figure 41.2.
2. Place your fi ngers inside the opening and squeeze
the latch. The side can now be pulled toward you and
removed. Place on a protective surface so as not to
damage the fi nish.
3. To replace the side, set the bottom in fi rst. Squeeze the
latch in an open position. Place the cast side into posi-
tion and then release the latch. The latch hooks onto a
bracket to hold the side in place.
1. Follow the proper shut down procedures as outlined on
page 35, Section 10.A.
Figure 41.2
Note: Instruction continue on page 42.