Quadra-Fire 31M-ACC-MBK Stove User Manual


 
July 7, 2011
7033-277I
Page 37
3100 Wood Stove Series (ACC)
R
G. Tube Channel Assembly Replacement
Removing Tube Channel Assembly
1. Remove the right side shield by removing 2 screws in the
back using a Phillips head screw driver.
2. Remove 4 screws from channel access cover and remove
cover.
3. Locate 2 channel nuts inside of chamber and remove
using a 7/16 socket wrench. Slide out tube channel
assembly.
NOTE: Soak the bolts with penetrating oil for at least 15
minutes before trying to remove them.
Replacing Tube Channel Assembly
1. Slide one gasket onto each tube.
2. Slide the tube channel assembly into side of fi rebox and
insert each tube into the corresponding hole in the tube
channel rack starting with the back hole fi rst.
3. Make sure tube channel assembly is ush against the
side of the stove and secure with channel nuts.
4. Re-install channel cover and side shield.
Channel
Access
Cover
Channel
Nuts (2)
Side Panel
Tube Channel
Assembly
Channel Cover
Screws (4)
Tube Channel Rack
Remove
2 Screws
Slide one gasket
over each tube
Figure 37.1
NOTE: Service Space
In order to replace the tube channel assembly a clearance
of 19 inches (483mm) is required on the right side of stove
in order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon-
nected from the chimney to proceed with the tube replace-
ment.